Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2015  |  Volume : 3  |  Issue : 1  |  Page : 24-28

Accuracy of Root ZX apex locator in primary teeth with different root canal irrigants: An in vivo study


Department of Pedodontics and Preventive Dentistry, College of Dental Sciences, Davangere, Karnataka, India

Correspondence Address:
Dr. I E Neena
Department of Pedodontics and Preventive Dentistry, College of Dental Sciences, Pavilion Road, Davangere - 577 004, Karnataka
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/2348-0149.158161

Rights and Permissions

Objective: The aim of this in vivo study was to determine the accuracy of 3 rd generation apex locator (Root ZX) in determining the canal length in primary teeth with normal saline and 0.12% chlorhexidine as root canal irrigants. Study Design: A total of 36 primary anterior teeth with minimum of 2/3 rd root lengths (indicated for extraction) were selected for this study. Working length (WL) was measured in dry, saline and chlorhexidine mode respectively and the standardized WL was measured using stereomicroscope under ×30. The data were evaluated using one-way ANOVA and Tukey's post-hoc test using SPSS software version 19 (IBM Company). The critical value for statistical significance was 5%. Results : For teeth without root resorption, the accuracy of Root ZX was 83% in dry mode and 92% in saline and chlorhexidine mode. For root canals with resorption the accuracy of Root ZX was 67% in dry mode and 83% in saline and chlorhexidine mode within ± 1 mm. However these figures decreased to 17%, 58% and 75% without resorption and 0%, 17% and 50% with resorption respectively for within ± 0.5. No significant differences were detected between the three different modes with the tolerance ± 1 mm under without resorption. However, significant difference was found without resorption as well as with resorption under tolerance ± 0.5 mm. Conclusion: The study concluded that Root ZX electronic Root apex locator is accurate with tolerance ± 1 mm in determining the root canal length in primary teeth without root resorption under different root canal irrigants that is, saline and chlorhexidine.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed5897    
    Printed329    
    Emailed0    
    PDF Downloaded507    
    Comments [Add]    
    Cited by others 1    

Recommend this journal